Reconstruction of the crane electrical system following the installation of emergency hoist brakes. SKET 250/32/2t crane located in the HVB II reactor hall. Hoist drives controlled by frequency converters. PLC-based control system with circuit diagnostics displayed on a touchscreen.
Environment
- Reactor hall
Interesting facts
The diagnostic system installed for the crane hoist is capable of evaluating operating conditions and preventing a suspended load from falling within a very short response time.